Sierra When you combine decades of experience with truly unique talents, great things can happen. TRICOR Coriolis flow meter technology may be a new name on the scene but our engineers have been intimately involved with the development and evolution of coriolis flowmeters since the beginning. In fact, many of the critical patents for coriolis meter technology bear Tricor engineers? names. TRICOR Coriolis Technology products were designed and engineered in Colorado & Wisconsin & Germany. Their state-of-the-art manufacturing facility in Germany is equipped with superior calibration and test equipment that guarantees the performance of your instrument from the time it arrives at your site. Their promise to you is that they will deliver high performance Coriolis technology, supported by the very gurus who crafted the originals.

 

 
Tricor Coriolis Flowmeters for Gases and Liquids
Click Photo for Spec Sheet

Description

Flow Range

Liquids

Accuracy

Pressure/Temperature

Features

TCM 0325
Photo

  • TRICOR® Coriolis Mass Flow Meter TCM 0325 for Gases and Liquids
  • Nominal Meter Size:        DN4 / 1/8″

  • Mass Flow Rate (max.):   325 kg/h / 11 lb/min
  • Volumetric Flow Rate (max.):       325 l/h / 1.31 gpm / 49 bbl/d

  • Any non-abrasive, chemically compatible liquid or gas (gas density >8kg/m³).

  • ACCURACY (LIQUIDS)
  • Basic Accuracy [Mass flow]:         ±0.1% of flow rate
  • Mass Flow Repeatability:               ±0.05% of flow rate
  • Basic Accuracy [Volume flow]:     ±0.15% of flow rate
  • Volume Flow Repeatability:          ±0.05% of flow rate
  • Zero Stability:     ±0.01% of full scale

  • Standard Pressure Rating:             up to 200 bar / 2900 psi
  • Process Temperature Range:        Standard: -40°C…+100°C/ Optional -60°C…+150°C

  • Robust for long life
  • Integrated pressure compensation- Minimal pressure effects despite dynamical pressure changes
  • Customised installation length
  • Excellent repeatability
  • Option for 345 bar (5000 psi)- For accurate chemical injection metering

TCM 0650
Photo

  •  TRICOR® Coriolis Mass Flow Meter TCM 0625 for Gases and Liquids
  • Nominal Meter Size:        DN4 / 1/8″

  • Mass Flow Rate (max.):   650 kg/h / 22 lb/min
  • Volumetric Flow Rate (max.):       650 l/h / 2.64 gpm / 98 bbl/d

  •  Any non-abrasive, chemically compatible liquid or gas (gas density >8kg/m³)

  • ACCURACY (LIQUIDS)
  • Basic Accuracy [Mass flow]:         ±0.1% of flow rate
  • Mass Flow Repeatability:               ±0.05% of flow rate
  • Basic Accuracy [Volume flow]:     ±0.15% of flow rate
  • Volume Flow Repeatability:          ±0.05% of flow rate
  • Zero Stability:     ±0.01% of full scale

  • Standard Pressure Rating:             up to 200 bar / 2900 psi
  • Process Temperature Range:        Standard: -40°C…+100°C/ Optional -60°C…+150°C

  • Robust for long life
  • Integrated pressure compensation
  • Minimal pressure effects despite dynamical pressure changes
  • Customised installation length
  • Excellent repeatability
  • Option for 345 bar (5000 psi)
  • For accurate chemical injection metering

TCM 1550
Photo

  • TRICOR® Coriolis Mass Flow Meter TCM 1550 for Gases and Liquids
  • Nominal Meter Size:        DN6 / 1/4″

  • Mass Flow Rate (max.):   1550 kg/h / 55 lb/min
  • Volumetric Flow Rate (max.):       1550 l/h / 6.59 gpm / 234 bbl/d

  •  Any non-abrasive, chemically compatible liquid or gas (gas density >8kg/m³).

  • ACCURACY (LIQUIDS)
  • Basic Accuracy [Mass flow]:         ±0.1% of flow rate
  • Mass Flow Repeatability:               ±0.05% of flow rate
  • Basic Accuracy [Volume flow]:     ±0.15% of flow rate
  • Volume Flow Repeatability:          ±0.05% of flow rate
  • Zero Stability:     ±0.01% of full scale

  • Standard Pressure Rating:             up to 200 bar / 2900 psi
  • Process Temperature Range:        Standard: -40°C…+100°C/ Optional -60°C…+150°C

  • Robust for long life
  • Integrated pressure compensation- Minimal pressure effects despite dynamical pressure changes
  • Customised installation length
  • Excellent repeatability
  • Option for 345 bar (5000 psi)- For accurate chemical injection metering

TCM 3100
Photo

  • TRICOR® Coriolis Mass Flow Meter TCM 3100 for Gases and Liquids
  • Nominal Meter Size:        DN6 / 1/4″

  • Mass Flow Rate (max.):   3100 kg/h / 110 lb/min
  • Volumetric Flow Rate (max.):       3100 l/h / 13.19 gpm / 467 bbl/d

  • Any non-abrasive, chemically compatible liquid or gas (gas density >8kg/m³).

  • ACCURACY (LIQUIDS)
  • Basic Accuracy [Mass flow]:         ±0.1% of flow rate
  • Mass Flow Repeatability:               ±0.05% of flow rate
  • Basic Accuracy [Volume flow]:     ±0.15% of flow rate
  • Volume Flow Repeatability:          ±0.05% of flow rate
  • Zero Stability:     ±0.01% of full scale

  • Standard Pressure Rating:             up to 200 bar / 2900 psi
  • Process Temperature Range:        Standard: -40°C…+100°C/ Optional -60°C…+150°C

  • Robust for long life
  • Integrated pressure compensation- Minimal pressure effects despite dynamical pressure changes
  • Customised installation length
  • Excellent repeatability
  • Option for 345 bar (5000 psi)- For accurate chemical injection metering

TCM 5500
Photo

  • TRICOR® Coriolis Mass Flow Meter TCM 5500 for Gases and Liquids
  • Nominal Meter Size:        DN15 / 1/2″

  • Mass Flow Rate (max.):   5500 kg/h / 202 lb/min
  • Volumetric Flow Rate (max.):       5500 l/h / 24.3 gpm / 830 bbl/d

  • Any non-abrasive, chemically compatible liquid or gas (gas density >8kg/m³).

  • ACCURACY (LIQUIDS)
  • Basic Accuracy [Mass flow]:         ±0.1% of flow rate
  • Mass Flow Repeatability:               ±0.05% of flow rate
  • Basic Accuracy [Volume flow]:     ±0.15% of flow rate
  • Volume Flow Repeatability:          ±0.05% of flow rate
  • Zero Stability:     ±0.01% of full scale

  • Standard Pressure Rating:             up to 200 bar / 2900 psi
  • Process Temperature Range:        Standard: -40°C…+100°C/ Optional -60°C…+150°C

  • Robust for long life
  • Integrated pressure compensation- Minimal pressure effects despite dynamical pressure changes
  • Customised installation length
  • Excellent repeatability
  • Option for 345 bar (5000 psi)- For accurate chemical injection metering

TCM 7900
Photo

  • TRICOR® Coriolis Mass Flow Meter TCM 7900 for Gases and Liquids
  • Nominal Meter Size:        DN15 / 1/2″

  • Mass Flow Rate (max.):   7900 kg/h / 290 lb/min
  • Volumetric Flow Rate (max.):       7900 l/h / 34.8 gpm / 1190 bbl/d

  •  Any non-abrasive, chemically compatible liquid or gas (gas density >8kg/m³).

  • ACCURACY (LIQUIDS)
  • Basic Accuracy [Mass flow]:         ±0.1% of flow rate
  • Mass Flow Repeatability:               ±0.05% of flow rate
  • Basic Accuracy [Volume flow]:     ±0.15% of flow rate
  • Volume Flow Repeatability:          ±0.05% of flow rate
  • Zero Stability:     ±0.01% of full scale

  • Standard Pressure Rating:             up to 100 bar / 1450 psi
  • Process Temperature Range:        Standard: -40°C…+100°C/ Optional -60°C…+150°C

  • Robust for long life
  • Integrated pressure compensation- Minimal pressure effects despite dynamical pressure changes
  • Customised installation length
  • Excellent repeatability
  • Optional net oil functionality 

TCM 028K
Photo

  • TRICOR® Coriolis Mass Flow Meter TCM 028K for Gases and Liquids
  • Nominal Meter Size:        DN25 / 1″

  • Mass Flow Rate (max.):   28000 kg/h / 1056 lb/min
  • Volumetric Flow Rate (max.):       28000 l/h / 126.6 gpm / 4226 bbl/d

  •  Any non-abrasive, chemically compatible liquid or gas (gas density >8kg/m³).

  • ACCURACY (LIQUIDS)
  • Basic Accuracy [Mass flow]:         ±0.1% of flow rate
  • Mass Flow Repeatability:               ±0.05% of flow rate
  • Basic Accuracy [Volume flow]:     ±0.15% of flow rate
  • Volume Flow Repeatability:          ±0.05% of flow rate
  • Zero Stability:     ±0.01% of full scale

  • Standard Pressure Rating:             up to 100 bar / 1450 psi
  • Process Temperature Range:        Standard: -40°C…+100°C/ Optional -60°C…+150°C

  • Robust for long life
  • Integrated pressure compensation- Minimal pressure effects despite dynamical pressure changes
  • Customised installation length
  • Excellent repeatability
  • Optional net oil functionality 

TCM 065K
Photo

  • TRICOR® Coriolis Mass Flow Meter TCM 065K for Gases and Liquids
  • Nominal Meter Size:        DN50 / 2″

  • Mass Flow Rate (max.):   65000 kg/h / 2400 lb/min
  • Volumetric Flow Rate (max.):       65000 l/h / 288 gpm / 9812 bbl/d

  • Any non-abrasive, chemically compatible liquid or gas (gas density >8kg/m³).

  • ACCURACY (LIQUIDS)
  • Basic Accuracy [Mass flow]:         ±0.1% of flow rate
  • Mass Flow Repeatability:               ±0.05% of flow rate
  • Basic Accuracy [Volume flow]:     ±0.15% of flow rate
  • Volume Flow Repeatability:          ±0.05% of flow rate
  • Zero Stability:     ±0.01% of full scale

  • Standard Pressure Rating:             up to 100 bar / 1450 psi
  • Process Temperature Range:        Standard: -40°C…+100°C/ Optional -60°C…+150°C

  • Robust for long life
  • Integrated pressure compensation- Minimal pressure effects despite dynamical pressure changes
  • Customised installation length
  • Excellent repeatability
  • Optional net oil functionality 

TCM 230K
Photo

  • TRICOR® Coriolis Mass Flow Meter TCM 230K for Gases and Liquids
  • Nominal Meter Size:        DN80 / 3″

  • Mass Flow Rate (max.):   230000 kg/h / 8433 lb/min
  • Volumetric Flow Rate (max.):       230000 l/h / 1012 gpm / 34700 bbl/d

  •  Any non-abrasive, chemically compatible liquid or gas (gas density >8kg/m³).

  • ACCURACY (LIQUIDS)
  • Basic Accuracy [Mass flow]:         ±0.1% of flow rate
  • Mass Flow Repeatability:               ±0.05% of flow rate
  • Basic Accuracy [Volume flow]:     ±0.15% of flow rate
  • Volume Flow Repeatability:          ±0.05% of flow rate
  • Zero Stability:     ±0.01% of full scale

  • Standard Pressure Rating:             up to 100 bar / 1450 psi
  • Process Temperature Range:        Standard: -40°C…+100°C/ Optional -60°C…+150°C

  • Robust for long life
  • Integrated pressure compensation- Minimal pressure effects despite dynamical pressure changes
  • Customised installation length
  • Excellent repeatability
  • Optional net oil functionality 

TCE 8000 & 6000 Transmitter
Photo

  • TRICOR® Coriolis Transmitters
  • Multi-variable Coriolis transmitter that can output flow rate, density, and temperature

  •  Outputs available:
  • Analog current output (up to 2)
  • Pulse/frequency output (0.5-10000 Hz)
  • Status output

  • Programmable control inputs
  • Interfaces available:
  • RS 485
  • HART®
  • Foundation Fieldbus
  • LCD Display

  • Hazardous area approvals:
  • ATEX
  • IECEx
  • cCSAus