| Click Photo for Spec Sheet |
500 series
|
Low flow electromagnetic flowmeter with PTFE liner. BSP connections. 3, 6, 10, 15 & 20mm diameter. 15mm & 20mm are standard sizes. |
|
At 2 m/s 0.85 to 30.5 litres/minute |
Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content. |
|
- PTFE Lining with three 316L stainless steel electrodes as standard;
- IP68 to 1.5m metres
- 501 series has PP liner, 10 bar & IP67
|
4000 series
|
Low flow electromagnetic flowmeter - the right choice for the automotive market. DN15 to DN50, hose connections, PN10, PBT & fibreglass lining |
±0.5% over flow range 0.5 to 5 m/s; maximum velocity 10 m/s. Converter normally separate. |
At 2 m/s 21.2 to 236 litres/minute depending on connection size. |
Any conductive liquid, must be greater than 10 microSiemens/centimetre. Accuracy not dependent on solids content. |
- 10 bar
- -25°C to +80°C
- -25°C to +120°C with separate converter (6.1m cable standard)
|
- PBT & Fibreglass lining with three 316L stainless steel electrodes as standard;
- IP67 NEMA 6
- Also available: 500 series has PTFE liner, 16 bar & IP68
|
1000 EL series
|
Extended linearity electromagnetic flowmeter with PTFE liner designed for wafer fitting between flanges. 25mm to 300mm |
±0.2% over flow range 0.5 to 5 m/s; turndown 1000:1; maximum velocity 10 m/s |
At 2 m/s between 59 and 8480 l/min depending on meter size |
Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content. |
- 40 bar (16bar over 200mm)
- -40°C to +180°C (for separate version); 80°C for the compact version
|
- PTFE Lining with three Hastelloy electrodes as standard;
- IP68 to 1.5 metres
- 1100J series has PBT liner, IP67, low cost
|
1100J Series
|
Lightweight, compact electromagnetic flowmeter with PBT liner designed for wafer fitting between flanges. 25mm - 150mm |
±0.2% over 0.5 to 5 m/s; maximum velocity 10 m/s |
At 2 m/s between 59 and 2121 l/min depending on meter size |
Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content. |
- 20 bar
- 0°C to +110°C (for separate version); 80°C for the compact version
|
- PBT Lining with three 316L stainless steel electrodes as standard;
- IP67
- 1000 series has PTFE liner and larger sizes
|
2200 EL series
|
Extended linearity electromagnetic flowmeter with PTFE liner designed for flange fitting |
±0.2% over 0.5 to 5 m/s; Turndown 1000:1; maximum velocity 10 m/s |
At 2 m/s between 59 and 15080 l/min depending on meter size |
Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content. |
- 6 to 64bar
- -20°C to +180°C (for separate version); 80°C for the compact version
|
- PTFE Lining with three Hastelloy electrodes as standard;
- Hard rubber Lining above 150mm
- IP68 to 1.5 meters
|
2500 El Series
|
Extended linearity electromagnetic flowmeter with PTFE or Ebonite liner designed for flange fitting. 450 to 2000mm |
±0.2% over 0.5 to 5 m/s; Turndown 1000:1; maximum velocity 10 m/s |
At 2 m/s between 1145 and 22619 m3/hr depending on meter size |
Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content. |
- 10 bar (mostly)
- -20°C to +80°C (for ebonite version); 180°C for the PTFE version
|
- Ebonite lining with three SS electrodes as standard;
- PTFE version
- IP68 to 1.5 meters
|
2400 Series
|
Hygienic electromagnetic flowmeter with PTFE liner |
±0.2% over flow range 0.5 to 5 m/s; maximum velocity 10 m/s |
At 2 m/s between 59 and 942 l/min depending on meter size |
Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content. |
- 16 bar
- -40°C to +140°C (for separate version); 60°C for the compact version
|
- PTFE Lining with two 316L electrodes as standard;
- IP68 to 1.5 meters
- 304SS externals
|
2700 Series
|
Insertion electromagnetic flowmeters with PTFE. Pipe size 80 to 3000mm |
3% of measured value with a flow velocity higher than 0.3m/s; maximum velocity 10 m/s |
Velocity range: 0 to 10m/s |
Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content. |
- 10/16 bar
- -40°C to +180°C (for separate version); 60°C for the compact version
|
- PTFE with 316L SS electrode as standard; pipe end 304SS
- IP68 to 1.5 meters
- 2660, low cost
- 2770, 16bar
- 2700, hot tap
|
| |
|
|
|
|
|
|