Sierra

KRAL flowmeters provide both sturdy design and high precision. For over 30 years, KRAL products have satisfied a wide range of customer requirements. This engineering experience and manufacturing capacity ensures both cost-effective and high quality production. The unit is supplied with the Litre Meter standard or Intrinsically-safe pick-up and pulse output transmitter system.  'Laboratory precision even in harsh industrial applications'.

spacer
  • KRAL Helical Screw Flowmeters
  • KRAL Fuel Consumpton System
  • KRAL Instrumentation
 

 

Click Photo for Spec Sheet Description Features Input Power Output Signals Other
BEM series
BEM Series

BEM 300 and 500; Electronic units coordinated to KRAL flowmeters and their diverse applications

  • 76x25mm LCD display
  • 5 robust micro-switches
  • Panel, wall or pipe mount

  • 90-260 Vac 50/60Hz
  • 24 Vdc ±20%

Scalable 4-20 mA or 0-10 Vdc, pulse output, Modbus

Optional temperature and pressure pulse compensation. Two channel, mass conversion, linearisation.

FlowPod
FlowPod

Display Instrument with Flow rate/Accumulated flow display and linearisation. Five 13mm and eleven 7mm digits.

  • 8 digit LCD display and unique analogue ribbon
  • Programming by RS485 or front panel
  • 16 point linearisation
  • Wall mounted

  • 24 Vdc
  • Supplies up to 15Vdc max 50mA

Pulse, 4-20mA, MODBUS as standard.

  • 8 digit LCD display and unique analogue ribbon
  • On site calibration

M.BDC60 Batcher
M.BDC60 Batcher

Display Instrument for Batching with Flow rate/Accumulated flow display and linearisation. Large LED character size.

  • 8 digit LED display
  • Programming and batch set by front panel
  • 16 point linearisation
  • Panel mounted

  • 24 Vdc
  • 95 to 265 Vac 50Hz/60Hz

Standard 2 channel flow alarm with SPCO relays (rated 240Vac 5A resistive and 3A inductive loads). Can also be configured for flow status and/or valve leakage. Pulse, 4-20mA & 0-5Vdc options

  • On site calibration mode
  • Total reset
  • Optional outputs

F112
F112

Flow rate/total and accumulated total display instrument, 15 point linearisation. Hazardous Area option.

  • Seven 17mm and eleven 8mm digits.
  • Direct or wall mount.

  • 8-28 Vdc.
  • 2-24 Vac/dc or 115-240 Vac supply option.

  • Pulse, 4-20mA, as standard.
  • MODBUS, RS485, 0-10V option
  • IP67 NEMA4X GRP enclosure, Aluminium option

  • For flow alarm option see F118
  • -30°C to +80°C
  • IP67 NEMA4X GRP enclosure, Aluminium option

F118
F118

Flow rate/total and accumulated total display instrument, 15 point linearisation. High/Low alarms. Hazardous Area option.

  • Seven 17mm and eleven 8mm digits.
  • Direct or wall mount.

  • 8-28 Vdc.
  • 2-24 Vac/dc or 115-240 Vac supply option.

  • Pulse, 4-20mA, as standard.
  • MODBUS, RS485, 0-10V option
  • IP67 NEMA4X GRP enclosure, Aluminium option

  • Without flow alarm option see F112
  • -30°C to +80°C
  • IP67 NEMA4X GRP enclosure, Aluminium option