Sierra   Litre Meter have manufactured the LM and MM range of pelton wheel turbine flowmeters since 1975. The VFF range of rotary piston positive displacement meters joined the line-up in 1985. Litre Meter specialise in low flow measurement. Many of the meters are customised to customers precise requirments particularly in the field of Oil & Gas.

 

Flow Meter Instrumentation
Click Photo for Spec Sheet Description Features Input Power Output Signals Other
FlowPod for VFF
LM06 Instrumentation for Pelton Wheel and VFF Flowmeters

State of the Art 2-wire display Instrument with Flow rate/Accumulated flow display and linearisation. Five 17mm and eleven 8mm digits. HART & 4-20mA as standard. Analogue Ribbon.

  • Custom LCD display
  • Programming by laptop, HART or magnet
  • 16+ point linearisation
  • Meter or remote mounted
  • Removeable memory card (LM-MC)
  • Exd or Exia

  • Loop powered
  • 24 Vdc
  • 12 to 30 Vdc (Exd or Exia)
  • 2 wire or 4 wire
  • Pulse
  • 4-20mA as standard
  • HART 7 as standard
  • Flow alarm
  • Reverse flow
  • Batch
  •  316 SS enclosure as standard
  • ATEX, IECEx, CSA US
  • IP66, IP68
  • 85mm diameter, 1.6kg
F018
LM06 Instrumentation for Pelton Wheel and VFF Flowmeters

 Flow rate/total and accumulated total display HART instrument, 15 point linearisation. Intrinsically Safe option.

  •  Seven 17mm and eleven 8mm digits.
  • Direct or wall mount.
  •  8-28 Vdc.
  • 2-24 Vac/dc or 115-240 Vac supply option.
  • Single Pulse, 4-20mA, as standard.
  • HART with specific DD
  • IP66, IP67 NEMA4X GRP enclosure, Aluminium option
  •  For flow alarm option see F118
  • -40C to +80C
  • IP67 NEMA4X GRP enclosure, Aluminium option
F112
LM06 Instrumentation for Pelton Wheel and VFF Flowmeters

Flow rate/total and accumulated total display instrument, 15 point linearisation. Hazardous Area option.

  • Seven 17mm and eleven 8mm digits.
  • Direct or wall mount.
  • 8-28 Vdc.
  • 2-24 Vac/dc or 115-240 Vac supply option.
  • Pulse, 4-20mA, as standard.
  • MODBUS, RS485, 0-10V option
  • IP67 NEMA4X GRP enclosure, Aluminium option
  • For flow alarm option see F118
  • -30C to +80C
  • IP67 NEMA4X GRP enclosure, Aluminium option
F118
LM06 Instrumentation for Pelton Wheel and VFF Flowmeters
Flow rate/total and accumulated total display instrument, 15 point linearisation. High/Low alarms. Hazardous Area option.
  • Seven 17mm and eleven 8mm digits.
  • Direct or wall mount.
  • 8-28 Vdc.
  • 2-24 Vac/dc or 115-240 Vac supply option.
  • Pulse, 4-20mA, as standard.
  • MODBUS, RS485, 0-10V option
  • IP67 NEMA4X GRP enclosure, Aluminium option
  • Without flow alarm option see F112
  • -30C to +80C
  • IP67 NEMA4X GRP enclosure, Aluminium option
M.BDC60 Batcher
LM06 Instrumentation for Pelton Wheel and VFF Flowmeters
Display Instrument for Batching with Flow rate/Accumulated flow display and linearisation. Large LED character size.
  • 8 digit LED display
  • Programming and batch set by front panel
  • 16 point linearisation
  • Panel mounted
  • 24 Vdc
  • 95 to 265 Vac 50Hz/60Hz
Standard 2 channel flow alarm with SPCO relays (rated 240Vac 5A resistive and 3A inductive loads). Can also be configured for flow status and/or valve leakage. Pulse, 4-20mA & 0-5Vdc options
  • On site calibration mode
  • Total reset
  • Optional outputs
FPod Exd for VFF
LM06 Instrumentation for Pelton Wheel and VFF Flowmeters

Display Instrument with Flow rate/Accumulated flow display and linearisation. Five 13mm and eleven 7mm digits. MODBUS and 4-20mA as standard.  Now replaced by the Litre Meter FlowPod

  • LCD display
  • Programming by laptop
  • 16 point linearisation
  • Meter or remote mounted
  • 24 Vdc
  • 12 to 40 Vdc

Pulse, 4-20mA, Flow alarm. HART, Foundation Fieldbus, Profi as option.

  • Painted aluminium for offshore environments, SS option
  • INMETRO, ATEX, UL
  • IP66, IPW66