North Sea pick 1 pick 2 pick 3 pick 4 pick 5 pick 6 pick 7 Ritter TG1 pick 8 pick 9 pick 10 pick 11 pick 12 pick 13 pick 14 pick 15 pick16 pick 17 pick 18 pick 19 pick 20 pick 21 pick 22 pick 23 pick 24 pick 25 pick 26 North Sea pick 1 pick 2 pick 3 pick 4 pick 5 pick 6 pick 7 pick 8 pick 9 pick 10 pick 11 pick 12 pick 13 pick 14 pick 15 pick16 pick 17 pick 18 pick 19 pick 20 pick 21 pick 22 pick 23 pick 24 pick 25 pick 26

Technologies
Pelton Wheel Helical Screw
Thermal Mass Industrial Turbine
VFF Meters Thermal Mass Capillary
Ultrasonic Vortex Shedding
Wet Drum Electromagnetic

Euromag Electromagnetic Flowmeters

Electromagnetic Flowmeters

A short guide to the Euromag range

Euromag Electromagnetic Flowmeters

A complete range of electromags from 3mm and upwards including insertion meters and instrumentation.

Automotive Use - coolant and air conditioning

The series 4000 is available in sizes 9 to 44mm for typical ranges of 0 to 15 up to 0 to 360 litres per minute.
The new MUT4000 coolant meter is designed specifically for automotive applications where high pressure and temperatures are an issue. The light, compact meter is constructed from PBT + fibre glass with a carbon steel enclosure designed to operate at a pressure rating of 10bar and maximum liquid temperature of 120°C and IP67. See 'downloads' for the data sheet.



Series 4000 - out of use at the moment - see downloads page for data sheet Automotive flowmeter 9 to 44mm

Low flow 3 to 20mm

The series 500 is available in sizes 3 to 20mm for typical ranges of 0 to 50 up to 0 to 2500 l/hr.



Series 500 Micro flowmeter 3 to 20mm

Higher flows 25 to 3000mm



Euromags larger devices are available in many sizes from 25mm and upward. The low cost 1100 series covers the range 40 to 125mm with a PBT liner.



Series 1000 40 to 300mm PTFE liner with higher temperature and pressure specifications to the 1100. PN40 140C IP68



Series 1100 40 to 125mm with PBT liner, PN10 & 100C. IP67.



Series 2200 Flanged meters 25mm up to 400mm.



Series 2500 Flanged meters 450mm up to 2000mm and bigger.



Series 2400 Hygienic flowmeter 25 to 100mm



Series 2700 Insertion flowmeters for 800mm+ lines.

Converters

Each of the flowmeters above requires a converter.



106B series converter suitable for panel mounting or installation in a control room.

  • Plastic cover (72 x 144 x 145 mm);
  • IP 44;
  • Analogue output 4-20 mA;
  • RS485 output;
  • ON/OFF output, open collector
  • programmable as: Alarm max flowrate; Alarm min flowrate; Alarm hardware
  • Flag for automatic full scale change
  • Bi-directional flowrate reading;
  • Measurement frequency 10/20 Hz;
  • Auto ranging;
  • Metric system (SI, UK, US);
  • Power supply:
  • 90...264 Vac 50-60 Hz or 24 Vac/dc 50-60 Hz;
  • Keyboard;
  • 2 lines 16 characters display;
  • Transparent flap door (optional)



308 series converter Suitable for harsh environments and more sophisticated outputs either ABS or Aluminium.

  • Easy to set (MENU);
  • Analogue output 4-20 mA;
  • RS 485 output (insulated);
  • Pulse and alarm ON/OFF output;
  • Bi-directional flowrate reading;
  • Measurement frequency 10/20 Hz;
  • Metric system (SI, UK, US);
  • Input for connection of TRM 100 programmer;
  • Power supply: 90...264 Vac 50-60 Hz or 24 Vac/dc 50-60 Hz;
  • Keyboard;
  • 2 lines 16 characters display;
  • Batching function; batching alarm;
  • Low consumption operating mode;
  • Empty pipe alarm (*);
  • Alarm min and max flowrate;
  • Alarm full scale change and reverse flow;
  • Modbus protocol (*) ;
  • Digital input for totalizer remote reset or batching start/stop;



308C series converter Suitable for harsh environments and more sophisticated outputs. Round Aluminium die cast case - IP68.

  • Easy to set (MENU);
  • Analogue output 4-20 mA;
  • RS 485 output (insulated);
  • Pulse and alarm ON/OFF output;
  • Bi-directional flowrate reading;
  • Measurement frequency 10/20 Hz;
  • Metric system (SI, UK, US);
  • Power supply: 90...264 Vac 50-60 Hz or 24 Vac/dc 50-60 Hz;
  • Optical keyboard with infrared pen;
  • 2 lines 16 characters display;
  • Batching function; batching alarm
  • Low consumption operating mode;
  • Empty pipe alarm;
  • Alarm min and max flowrate;
  • Alarm full scale change and reverse flow;
  • Modbus protocol (*) ;
  • Digital input for totalizer remote reset or batching start/stop;



108 series converter Most complete converter, recommended for 500mm and above and for noisy environments.:

  • Die cast aluminium case (280 x 180 x 115 mm);
  • IP 67;
  • Digital Input;
  • Input for connection of TRM 100 programmer;
  • Insulated current output 4-20 mA;
  • Insulated RS 485 interface;
  • Second RS 485 interface (*);
  • RS 232 interface (*);
  • Hardware alarm ON/OFF output 24 Vdc;
  • 2 relay output (*);
  • Bi-directional flowrate reading;
  • Measurement frequency 12.5/25/50 Hz;
  • Metric system (SI, UK, US);
  • Power supply: 90...264 Vac 50-60 Hz or 24 Vac/dc 50-60 Hz;
  • Pulses/frequency output 24 Vdc (max fr. 10.000 Hz);
  • Batching function;
  • Keyboard;
  • 2 lines 16 characters display;
  • Empty pipe detection;
  • Auto ranging (dual range);
  • Output safe from over voltage;