North Sea pick 1 pick 2 pick 3 pick 4 pick 5 pick 6 pick 7 pick 8 pick 9 pick 10 pick 11 pick 12 pick 13 pick 14 pick 15 pick16 pick 17 pick 18 pick 19 pick 20 pick 21 pick 22 pick 23 pick 24 pick 25 pick 26 North Sea pick 1 pick 2 pick 3 pick 4 pick 5 pick 6 pick 7 pick 8 pick 9 pick 10 pick 11 pick 12 pick 13 pick 14 pick 15 pick16 pick 17 pick 18 pick 19 pick 20 pick 21 pick 22 pick 23 pick 24 pick 25 pick 26

Digmesa

Sierra

DIGMESA produces high-quality precision flowmeters and high-tech electronics for the food and non-food sectors. With these devices, wine, beer, fruit juices, cola, mineral water and milk, as well as chemically aggressive media, can be precisely measured, regulated, monitored and dispensed. The range of applications is exceptionally diverse, as DIGMESA flowmeters are unaffected even by fluids such as acids and alkalis. Components produced by DIGMESA are to be found in laboratories, hospitals, research and production facilities, as well as in coffee machines, automatic washing machines and beer dispensing systems - even on the other side of the world. At Sydney airport, for example, no drink passes over the bar without being dispensed and registered by a DIGMESA measuring device.

  • Digmensa Products
Digmesa Products
Click Photo for Spec Sheet

Description

Flow Range

Liquids

Accuracy

Pressure/Temperature

Features

FHKSC

Very low cost, precise flowmeter in Arnite, specially designed for coffee machines that use vibratory pumps. With push-on connections. PVDF option.

0.03 to 2.00 l/min depending on nozzle diameter 1.00 to 2.00 mm

Any non abrasive, chemical compatible low viscosity liquid.

  • ±2% reading - linearity.
  • ±0.25% repeatability.

Pressures up to 0.3 bar at 20°C. Temperature range -10°C to +65°C.

Thanks to its closure system, the water outlet side can be assembled in four different positions. Central sprayed fastening pin Ø 2.8mm x 7.5mm. Recommended washer disk: Quicklock® Benzing Ø 3mm or Starlock P-6490 Ø 3mm. Designed to be installed before the pump.

FH

Low cost, precise flowmeter in brass. With 1/4" BSP connections.

0.04 to 7.84 l/min depending on nozzle diameter 1.00 to 6.00 mm

Any non abrasive, chemical compatible low viscosity liquid.

  • ±2% reading - linearity.
  • ±0.25% repeatability.

Pressures up to 20 bar at 20°C. Temperature range -10°C to +100°C.

Inlet and outlet on the same side, compact design, great working range, depending on the nozzle diameter. Widely fitted to commercial coffee machines.

FHK

Low cost, precise flowmeter used in coffee machines and postmix systems.

0.027 to 8.3 l/min depending on nozzle diameter 1.00 to 5.60 mm

Any non abrasive, chemical compatible low viscosity liquid.

  • ±2% reading - linearity.
  • ±0.25% repeatability.

Pressures up to 20 bar at 20°C. Temperature range -10°C to +65°C.

Arnite, Ryton or PVDF meter ideal for general applications with low pressure and temperatures. Inlet and outlet on the same side, compact design, great working range, depending on the nozzle diameter.

FHKU

Low cost, precise flowmeter developed for higher flows. With 1/4", 1/2" or John Guest connections. Optional LCD. Arnite or PVDF

0.04 to 30 l/min depending on nozzle diameter 1.00 to 10.00 mm

Any non abrasive, chemical compatible low viscosity liquid.

  • ±2% reading - linearity.
  • ±0.25% repeatability.

Pressures up to 10 bar at 20°C. Temperature range 0°C to +60°C.

Linear inlet and outlet. Time and date administration, upward or backwards counters, history with date, instantaneous value announcement, automatic impulse calibration, litres and /or alarm-date, security code prevents tampering by unauthorised persons. Current supply over lithium battery. With a battery change all attitudes and values are stored.

FF

Low cost, precise flowmeter in Arnite or PVDF. With 1/2" or 5/8" BSP or John Guest connections. This flowmeter is employed with great success in beer and premix dispensing systems.

0.22 to 15.75 l/min depending on nozzle diameter 4.00 to 6.00 mm

Any non abrasive, chemical compatible low viscosity liquid.

  • ±2% reading - linearity.
  • ±0.25% repeatability.

Pressures up to 5.5 bar at 20°C. Temperature range -10°C to +65°C. (PVDF 100°C)

By means of its special jewelled bearing, its fitting position can be freely selected. Inlet and outlet are freely selectable.

EPI

Low cost, highly precise flowmeter in Arnite or PEEK with 1/4"BSP or John Guest fittings. Epicycloid gears. Syrup, oils and concentrates.

0.06 to 16 l/min depending on viscosity.

Any non abrasive, chemical compatible higher viscosity liquid.

  • ±1% reading - linearity.
  • ±0.25% repeatability.

Pressures up to 10 bar at 20°C. Temperature range -10°C to +65°C. (PVDF 100°C)

Highly viscous media, high temperatures, high flow rates with low pressure loss and good chemical resistance.