North Sea pick 1 pick 2 pick 3 pick 4 pick 5 pick 6 pick 7 pick 8 pick 9 pick 10 pick 11 pick 12 pick 13 pick 14 pick 15 pick16 pick 17 pick 18 pick 19 pick 20 pick 21 pick 22 pick 23 pick 24 pick 25 pick 26 North Sea pick 1 pick 2 pick 3 pick 4 pick 5 pick 6 pick 7 pick 8 pick 9 pick 10 pick 11 pick 12 pick 13 pick 14 pick 15 pick16 pick 17 pick 18 pick 19 pick 20 pick 21 pick 22 pick 23 pick 24 pick 25 pick 26

Euromag

This page has been updated & will redirect in a few seconds

Sierra

Euromag provides a full lineup of electromagnetic flow meters for the industrial and sanitary markets from 3mm to 2000mm, with various liner materials and a wide range of flows. These meters are suitable for industries from water, wastewater, foods, beverage, chemical, liquids containing solid matter steel, nonferrous metals, fertilizers, inorganic chemicals, pulp and paper, and polymer chemicals.

  • spacerElectromagnetic Flowmeterspacer
  • spacerElectromagnetic Converterspacer
Electromagnetic Flowmeters
Click Photo for Spec Sheet

Description

Accuracy

Flow range

Liquid

Max. Pressures/Temperature

Features

500 series
Euromag11

Low flow electromagnetic flowmeter with PTFE liner. BSP connections. 3, 6, 10, 15 & 20mm diameter. 15mm & 20mm are standard sizes.

±0.2% over flow range 0.5 to 5 m/s; maximum velocity 10 m/s

At 2 m/s 0.85 to 30.5 litres/minute

Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content.

  • 16 bar
  • -20°C to +160°C (Compact version 80°C)

  • PTFE Lining with three 316L stainless steel electrodes as standard;
  • IP68 to 1.5m metres
  • 501 series has PP liner, 10 bar & IP67

501 series
Euromag11

Low flow electromagnetic flowmeter with PP liner. BSP connections. 3, 6, 10, 15 & 20mm diameter. 15mm & 20mm are standard sizes.

±0.2% over flow range 0.5 to 5 m/s; maximum velocity 10 m/s. Converter normally separate.

At 2 m/s 0.85 to 30.5 litres/minute

Any conductive liquid, must be greater than 10 microSiemens/centimetre. Accuracy not dependent on solids content.

  • 10 bar
  • -20°C to +60°C

  • PTFE Lining with three 316L stainless steel electrodes as standard;
  • IP67
  • 500 series has PTFE liner, 16 bar & IP68

4000 series
Euromag11

Low flow electromagnetic flowmeter - the right choice for the automotive market. DN15 to DN50, hose connections, PN10, PBT & fibreglass lining

±0.5% over flow range 0.5 to 5 m/s; maximum velocity 10 m/s. Converter normally separate.

At 2 m/s 21.2 to 236 litres/minute depending on connection size.

Any conductive liquid, must be greater than 10 microSiemens/centimetre. Accuracy not dependent on solids content.

  • 10 bar
  • -25°C to +80°C
  • -25°C to +120°C with separate converter (6.1m cable standard)

  • PBT & Fibreglass lining with three 316L stainless steel electrodes as standard;
  • IP67 NEMA 6
  • Also available: 500 series has PTFE liner, 16 bar & IP68

1000 EL series
Euromag11

Extended linearity electromagnetic flowmeter with PTFE liner designed for wafer fitting between flanges. 25mm to 300mm

±0.2% over flow range 0.5 to 5 m/s; turndown 1000:1; maximum velocity 10 m/s

At 2 m/s between 59 and 8480 l/min depending on meter size

Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content.

  • 40 bar (16bar over 200mm)
  • -40°C to +180°C (for separate version); 80°C for the compact version

  • PTFE Lining with three Hastelloy electrodes as standard;
  • IP68 to 1.5 metres
  • 1100J series has PBT liner, IP67, low cost

1100J Series
Euromag11

Lightweight, compact electromagnetic flowmeter with PBT liner designed for wafer fitting between flanges. 25mm - 150mm

±0.2% over 0.5 to 5 m/s; maximum velocity 10 m/s

At 2 m/s between 59 and 2121 l/min depending on meter size

Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content.

  • 20 bar
  • 0°C to +110°C (for separate version); 80°C for the compact version

  • PBT Lining with three 316L stainless steel electrodes as standard;
  • IP67
  • 1000 series has PTFE liner and larger sizes

2200 EL series
Euromag11

Extended linearity electromagnetic flowmeter with PTFE liner designed for flange fitting

±0.2% over 0.5 to 5 m/s; Turndown 1000:1; maximum velocity 10 m/s

At 2 m/s between 59 and 15080 l/min depending on meter size

Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content.

  • 6 to 64bar
  • -20°C to +180°C (for separate version); 80°C for the compact version

  • PTFE Lining with three Hastelloy electrodes as standard;
  • Hard rubber Lining above 150mm
  • IP68 to 1.5 meters

2500 El Series
Euromag11

Extended linearity electromagnetic flowmeter with PTFE or Ebonite liner designed for flange fitting. 450 to 2000mm

±0.2% over 0.5 to 5 m/s; Turndown 1000:1; maximum velocity 10 m/s

At 2 m/s between 1145 and 22619 m3/hr depending on meter size

Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content.

  • 10 bar (mostly)
  • -20°C to +80°C (for ebonite version); 180°C for the PTFE version

  • Ebonite lining with three SS electrodes as standard;
  • PTFE version
  • IP68 to 1.5 meters

2400 Series
Euromag11

Hygienic electromagnetic flowmeter with PTFE liner

±0.2% over flow range 0.5 to 5 m/s; maximum velocity 10 m/s

At 2 m/s between 59 and 942 l/min depending on meter size

Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content.

  • 16 bar
  • -40°C to +140°C (for separate version); 60°C for the compact version

  • PTFE Lining with two 316L electrodes as standard;
  • IP68 to 1.5 meters
  • 304SS externals

2700 Series
Euromag11

Insertion electromagnetic flowmeters with PTFE. Pipe size 80 to 3000mm

3% of measured value with a flow velocity higher than 0.3m/s; maximum velocity 10 m/s

Velocity range: 0 to 10m/s

Any conductive liquid, must be greater than 5 microSiemens/centimetre. Accuracy not dependent on solids content.

  • 10/16 bar
  • -40°C to +180°C (for separate version); 60°C for the compact version

  • PTFE with 316L SS electrode as standard; pipe end 304SS
  • IP68 to 1.5 meters
  • 2660, low cost
  • 2770, 16bar
  • 2700, hot tap
Electromagnetic Converters
Click Photo for Spec Sheet

Description

Features

Input Power

Output Signals

Other

MC106
MC106

Essential Electromagnetic converter. MC106A: Wall or Direct Mount. 106B: Panel Mount only.

  • 4-20mA
  • MC106A: IP67, optional keyboard, optional display
  • MC106B: IP44, keyboard & display

  • 90-264 Vac 50-60 Hz.
  • 24 Vac/dc 50-60 Hz

  • Alarm max flow rate; Alarm min flow rate ; Alarm hardware
  • 4-20mA
  • RS485

  • Measurement Frequency 10/20Hz
  • Bidirectional

MC608
MC608A MC608B mains or battery powered electromgnetic flowmeter converter

Versatile Electromagnetic converter. Wall or Direct Mount. Mains or battery powered.

  • 4-20mA
  • IP67/68, keyboard & display
  • Compact or separate

  • 90-264 Vac 50-60 Hz.
  • 24 Vac/dc 50-60 Hz
  • Battery powered or 12/24Vac/dc - MC608B

  • Alarm max flow rate; Alarm min flow rate ; Alarm hardware
  • 4-20mA
  • RS485 or MODBUS RTU
  • Datalogger

  • Programmable Measurement Frequency upto 5 Hz
  • Bidirectional

MC308C
MC308C

Versatile Electromagnetic converter. Round diecast aluminium with LCD display and infrared light pen.

  • 4-20mA
  • IP68, keyboard & display
  • Compact or separate

  • 90-264 Vac 50-60 Hz.
  • 24 Vac/dc 50-60 Hz

  • Alarm max flow rate; Alarm min flow rate ; Alarm hardware
  • 4-20mA
  • RS485

  • Measurement Frequency 10/20Hz
  • Bidirectional

MC108
MC108

Versatile Electromagnetic converter. Wall or Direct Mount.

  • 4-20mA
  • IP67, keyboard & display
  • Compact or separate

  • 90-264 Vac 50-60 Hz.
  • 24 Vac/dc 50-60 Hz

  • Alarm max flow rate; Alarm min flow rate ; Alarm hardware
  • 4-20mA
  • RS485

  • Measurement Frequency 12.5/60Hz