Sierra Instruments manufacturers high performance mass flow meters and mass flow controllers for nearly any gas, liquid, or steam application. Thermal Mass, Transit-Time Ultrasonic, Vortex Shedding and Multivariable flow meters are available in both standard and customized versions for applications in laboratory, industrial, and hazardous environments. Sierra's flow measurement technologies precisely measure or control very low flows down to less than 1 sccm full scale as well as extremely high flows of gas, liquid, and steam. |
| Mass Flow Meters and Controllers | ||||||
Click Photo for Spec Sheet |
Description |
Accuracy, Flow range |
Gas & Max. Pressures |
Input Power |
Output Signals |
Features |
Digital high performance gas mass flow meters and controllers; multi-gas capability; stainless steel construction. Now Smart Trak 2. |
|
|
24 Vdc, 12 Vdc (optional) |
RS-232, 0-5 Vdc, 0-10 Vdc 1-5 Vdc, 4-20 mA |
Pilot module for function control. Dial-A-Gas ® technology. Fast response control valve. Digital. |
|
Specifically designed for most gases down to 0.1 sccm |
|
|
24 Vdc |
0-5 Vdc, 4-20 mA and 1-5 Vdc, 0-10 Vdc |
Unique Pilot Module allows control and display of the following functions: Gas, Setpoint, Units, Output, valve and Full Scale |
|
Low-cost gas mass flow meter with tiltable digital readout; nylon or aluminium construction. |
|
|
12 to 18 Vdc, 24 Vdc (optional) |
0-5 Vdc, 4-20 mA |
Low cost nylon body. Blind meters and controllers available. |
|
Low-cost gas mass flow meter with tiltable digital readout; stainless steel construction. |
|
|
12 to 18 Vdc, 24 Vdc (optional) |
0-5 Vdc, 4-20 mA |
Low cost stainless steel body. Blind meters and controllers available. |
|
Low-cost gas mass flow controller with digital readout; nylon construction. |
|
|
24 Vdc |
0-5 Vdc, 4-20 mA simultaneous |
Low cost nylon body. Blind controllers available. User-selectable local or remote set point |
|
High performance gas mass flow meters and controllers; stainless steel construction. |
|
|
± 15 Vdc |
0-5 Vdc, 4-20 mA |
High accuracy. High capacity / flow rate. Blind meters and controllers available. |
|
Digital high performance NEMA 6/IP67 gas mass flow meters and controllers with stainless steel process fittings; multi-gas capability; stainless steel construction. |
|
|
24 Vdc |
RS-232, 0-5 Vdc, 0-10 Vdc 1-5 Vdc, 4-20 mA |
|
|
Digital high performance NEMA 6/IP67 gas mass flow meters and controllers with 316 stainless steel flanges; multi-gas capability; stainless steel construction. |
|
|
24 Vdc |
RS-232, 0-5 Vdc, 0-10 Vdc 1-5 Vdc, 4-20 mA |
|
|
Sierra Instrumentation |
|||||||
Click Photo for Spec Sheet |
Description |
Features |
Input Power |
Output Signals |
Other |
||
Ultra-compact digital control/readout and power supply system that is designed to operate a single MFM or MFC |
|
|
|
|
|||
Digital control/readout and power supply system that is designed to operate up to 4 MFMs or MFCs |
|
|
|
|
|||
With its advanced capabilities, the Compod™, coupled with Sierra’s Smart-Trak® 2 Model 100 mass flow meters or controllers greatly simplifies basic flow control installations and permits networking of multiple instruments using open-source MODBUS RTU protocol. |
Two digital outputs and one analog input can be configured by the user for a wide variety of process controls including:
|
|
|
Compod can be utilized in many common gas process control applications. In simple systems, it replaces expensive PLCs or computers and controls the process directly. In others, it is a key link between a master computer or process controller and the gas control instruments. |
|||
| Transit Time Ultrasonic Flow Meters | |||||||
Click Photo for Spec Sheet |
Description |
Accuracy, Flow Range |
Fluid Size |
Input Power |
Output Signals |
Features |
|
Ultrasonic flowmeter system incorporating digital signal processing. Innova-Sonic offers a low power consumption, clear display and user friendly menu selection. |
|
Liquids - non-intrusive so not subject to liquid type or pressure. Pipe Size: 25mm to 5000mm
|
|
Analog: 0/4 to 20mA (max load 75Ω), Pulse output: 0 to 9999Hz, OCT, (min. and max. frequency is adjustable), Relay output: RS232, RS485 |
Wall mounted, panel mounted or energy meter versions available. (-40°C to 150°C) |
||
In-line Ultrasonic flowmeter system incorporating digital signal processing. Innova-Sonic offers a low power consumption, clear display and user friendly menu selection. 1" to 10". |
|
Liquids - Pipe Size: 25mm to 250mm Any clean liquid, can tolerate small amounts of suspended solids and air bubbles |
|
Analog: 0/4 to 20mA (max load 75Ω), Pulse output: 0 to 9999Hz, OCT, (min. and max. frequency is adjustable), Relay output: RS232, |
Wall mounted, panel mounted or energy meter versions available. -40 to +80°C |
||
Fully field portable ultrasonic system complete with spare battery pack, non-invasive clamp-on transducers, mounting hardware and a unique PalmOne® Personal Digital Assistant (PDA) interface for a totally self-contained measurement package. |
|
Liquids - non-intrusive so not subject to liquid type or pressure. Pipe Size: 25mm to 5000mm |
|
Analogue: 0/4 to 20 mA (max load 750Ω) |
PalmOne® 256 MB Tungsten™ T5 PDA with Bluetooth wireless facility. Battery power supply with recharge port and spare battery as standard. -40°C to 80°C |
||
| Multivariable Vortex Mass Flowmeters | |||||||
Click Photo for Spec Sheet |
Description |
Accuracy, Flow Range |
Fluid, Max. pressures |
Input Power |
Output Signals |
Features |
|
In-Line Multivariable Mass Flow Meter; Hazardous Area Approvals: FM, CSA, & CE, Smart Electronics; In-Line flow body sizes from 1/4" to 8” |
|
|
|
|
|
||
|
|
|
|
|
|
||
| Mass Flow Calibrators | |||||||
Click Photo for Spec Sheet |
Description |
Accuracy, Flow Range |
Gas & Max. Pressures |
Input Power |
Output Signals |
Features |
Features |
High-precision, cost-effective calibration. Primary Standard. Manufactured to ISO 17025 Standards |
±0.4% reading, 5sccm to 50slpm |
Suitable for most non-corrosive gases |
AC Charger/Adapter: 100-240 Vac, 50-60 Hz |
Back-lit LCD display, RS232 serial port with software, parallel printer port (for dedicated printer) |
|
|
|
High-precision, cost-effective calibration. Primary Standard. Manufactured to ISO 17025 Standards |
±0.15% reading, 5sccm to 50slpm |
Suitable for most non-corrosive gases |
AC Charger/Adapter: 100-240 Vac, 50-60 Hz |
Back-lit LCD display, RS232 serial port with software, parallel printer port (for dedicated printer) |
|
|
|
High-precision, cost-effective calibration. Primary Standard. Manufactured to ISO 17025 Standards in NVLAP certified laboratory |
±0.25% reading, 5slpm to 500slpm, 4 psi (270 mbar) Differential maximum |
Suitable for most non-corrosive gases |
AC Charger/Adapter: 100-240 Vac, 1.6 A (max), 50-60 Hz |
Back-lit LCD display, RS232 serial port with software, parallel printer port (for dedicated printer) |
|
|
|
| Innova-Switch™ Flow & Level Switches | |||||||
Click Photo for Spec Sheet |
Description |
Accuracy, Flow Range |
Fluid & Max. Pressure |
Input Power |
Output Signal |
Features |
Features |
State-of-the-art in gaseous and liquid flow switching or liquid level control. High-resolution thermal differential technique. |
|
Gases and liquids up to 3000psi (207bar), -70 to 485°C model dependent |
|
5A. 250 Vac. DPDT with fail safe capability |
CE, CENELEC and CSA approvals |
316 SS standard. Hastelloy, Monel, Inconel or other materials optional |
|