North Sea pick 1 pick 2 pick 3 pick 4 pick 5 pick 6 pick 7 pick 8 pick 9 pick 10 pick 11 pick 12 pick 13 pick 14 pick 15 pick16 pick 17 pick 18 pick 19 pick 20 pick 21 pick 22 pick 23 pick 24 pick 25 pick 26 North Sea pick 1 pick 2 pick 3 pick 4 pick 5 pick 6 pick 7 pick 8 pick 9 pick 10 pick 11 pick 12 pick 13 pick 14 pick 15 pick16 pick 17 pick 18 pick 19 pick 20 pick 21 pick 22 pick 23 pick 24 pick 25 pick 26

Sierra

Sierra

Sierra Instruments manufacturers high performance mass flow meters and mass flow controllers for nearly any gas, liquid, or steam application. Thermal Mass, Transit-Time Ultrasonic, Vortex Shedding and Multivariable flow meters are available in both standard and customized versions for applications in laboratory, industrial, and hazardous environments. Sierra's flow measurement technologies precisely measure or control very low flows down to less than 1 sccm full scale as well as extremely high flows of gas, liquid, and steam.

  • Capillary Thermal
  • Industrial Thermal
  • Instrumentation
  • Ultrasonic
  • Vortex
  • Calibrator
  • Flow/Level Switch
Mass Flow Meters and Controllers
Click Photo for Spec Sheet

Description

Accuracy, Flow range

Gas & Max. Pressures

Input Power

Output Signals

Features

100 Series Smart-Trak®
205 Innova-Sonic®

Digital high performance gas mass flow meters and controllers; multi-gas capability; stainless steel construction. Now Smart Trak 2.

  • Accuracy: ±1% of full scale
  • ±0.7% of reading plus 0.3% of full scale (optional)
  • Flow Range: 0-4 sccm to 0-1000 slpm

  • Gas: All clean gases including corrosives and reactives.
  • Max. Pressure: 500 psig (34 barg)
  • Dial-A-Gas: 10 pre-programmed gases, user selectable

24 Vdc, 12 Vdc (optional)

RS-232, 0-5 Vdc, 0-10 Vdc 1-5 Vdc, 4-20 mA

Pilot module for function control. Dial-A-Gas ® technology. Fast response control valve. Digital.

101 Micro-Trak™
205 Innova-Sonic®

Specifically designed for most gases down to 0.1 sccm

  • Accuracy: ±1.0% of full scale
  • Flow Range: 0-4 sccm

  • Gas: All clean gases including corrosives and reactives.
  • Max. Pressure: 500 psig (34 barg)

24 Vdc

0-5 Vdc, 4-20 mA and 1-5 Vdc, 0-10 Vdc

Unique Pilot Module allows control and display of the following functions: Gas, Setpoint, Units, Output, valve and Full Scale

820 Top-Trak©
205 Innova-Sonic®

Low-cost gas mass flow meter with tiltable digital readout; nylon or aluminium construction.

  • Accuracy: ±1.5% of full scale
  • Flow Range: Model 822/824: 0-10 sccm to 0-50 slpm
  • Model 826/827: 0-75 slpm to 0-175 slpm

  • Gas: Air and non corrosive, non reactive gases
  • Max. Pressure 150 psig (10 barg)

12 to 18 Vdc, 24 Vdc (optional)

0-5 Vdc, 4-20 mA

Low cost nylon body. Blind meters and controllers available.

820 S Top-Trak©
205 Innova-Sonic®

Low-cost gas mass flow meter with tiltable digital readout; stainless steel construction.

  • Accuracy: ±1.5% of full scale [±1% of full scale (optional)]
  • Flow Range: 0-10 sccm to 0-500 slpm

  • Gas: All clean gases including corrosives and reactives.
  • Max. Pressure: 500 psig (34 barg)

12 to 18 Vdc, 24 Vdc (optional)

0-5 Vdc, 4-20 mA

Low cost stainless steel body. Blind meters and controllers available.

810 Mass-Trak®
205 Innova-Sonic®

Low-cost gas mass flow controller with digital readout; nylon construction.

  • Accuracy: ±1.5% of full scale
  • Flow Range: 0-10 sccm to 0-50 slpm

  • Gas: All clean gases including corrosives and reactives.
  • Max. Pressure: 150 psig (10 barg)

24 Vdc

0-5 Vdc, 4-20 mA simultaneous

Low cost nylon body. Blind controllers available. User-selectable local or remote set point

830-840 Side-Trak©
205 Innova-Sonic®

High performance gas mass flow meters and controllers; stainless steel construction.

  • Accuracy: ±1% of full scale
  • Flow Range: 0-10 sccm to 5600 slpm

  • Gas: All clean gases including corrosives and reactives.
  • Max. Pressure: 500 psig (34 barg)

± 15 Vdc

0-5 Vdc, 4-20 mA

High accuracy. High capacity / flow rate. Blind meters and controllers available.

180 Series Max-Trak®
205 Innova-Sonic®

Digital high performance NEMA 6/IP67 gas mass flow meters and controllers with stainless steel process fittings; multi-gas capability; stainless steel construction.

  • Accuracy: ±1% of full scale
  • Flow Range: 0-10 slpm to 0-1000 slpm

  • Gas: All clean gases including corrosives, toxics and reactives.
  • Max. Pressure: 500 psig (34 barg)
  • Dial-A-Gas: 10 pre-programmed gases, user selectable

24 Vdc

RS-232, 0-5 Vdc, 0-10 Vdc 1-5 Vdc, 4-20 mA

  • Pilot module for function control.
  • Dial-A-Gas ® technology.
  • Fast response control valve.
  • Digital.

180 Series Max-Trak® Flanged
205 Innova-Sonic®

Digital high performance NEMA 6/IP67 gas mass flow meters and controllers with 316 stainless steel flanges; multi-gas capability; stainless steel construction.

  • Accuracy: ±1% of full scale
  • Flow Range: 0-10 slpm to 0-1000 slpm

  • Gas: All clean gases including corrosives, toxics and reactives.
  • Max. Pressure: 500 psig (34 barg)
  • Dial-A-Gas: 10 pre-programmed gases, user selectable

24 Vdc

RS-232, 0-5 Vdc, 0-10 Vdc 1-5 Vdc, 4-20 mA

  • Pilot module for function control.
  • Dial-A-Gas ® technology.
  • Fast response control valve.
  • Digital.
Industrial Thermal Mass Flowmeters
Click Photo for Spec Sheet

Description

Accuracy, Flow range

Gas & Max Pressures

Input Power

Output Signals

Features

640S Steel-Mass™
640S Steel-Mass™

Insertion mass flow meters; NEMA 4X and Hazardous Area Approvals: FM, ATEX, CSA, EEx, PED, CE, Cenelec; Smart electronics; Insertion probe lengths 6” to 36”

+/- 2% of reading from 10% to 100% of calibrated range & 0.5% of full scale below 10%; 0.2% repeatability Flow range up to 20000 sfpm

Most gases compatible with 316 L stainless steel Pressures: NPT & compression fittings 500psi (35bar); flange ratings as appropriate

18-30 Vdc 100 to 240 Vac, 50/60 Hz (optional)

0-5 Vdc 0-10 Vdc 4-20 mA Pulse Modbus FFB Profibus RS232

Field Validation Low pressure drop Alarms and Totaliser Low-flow cut off Robust

780S Flat-Trak™
780S Flat-Trak™

In-line mass flow meters; NEMA 4X and Hazardous Area Approvals: FM, ATEX, CSA, EEx, PED, CE, Cenelec; Smart electronics; Body size 1/4" to 8" NPT, Buttweld or ANSI

Accuracy is +/-1% of reading, 0.5% of full scale repeatability Flow Range: 0-0.7 nm³/h to 0-20000 nm³/h

Most gases compatible with 316 L stainless steel Pressures: 500psi (35bar) NPT, flange ratings as appropriate

18-30 Vdc 100 to 240 Vac, 50/60 Hz (optional)

0-5 Vdc 0-10 Vdc 4-20 mA Pulse Modbus FFB Profibus RS232

Field Validation Low pressure drop Alarms and Totaliser Low-flow cut off Robust Built in flow conditioners provide compact installation

670S Multi-Trak™
670S Multi-Trak™

High-Performance Multi-Point Mass Flow Meter System For Large Ducts & Stacks that have non-uniform velocity profiles, high turn-down requirements, dirty gas streams, wide temperature ranges and fast velocity and temperature changes. CE, CSA, ATEX, FM, IP65. With Sierra HMI.

Accuracy +/- 1 % of reading plus 0.5% of full scale.

Most gases compatible with 316 L stainless steel. Pressures: up to 70barg. Temperatures to 177°C (option: 400°C).

18-30 Vdc (regulated), 825 mA per point

Linear 4-20 mA proportional to grand-average flow signal

Innovative and user-friendly HMI offers advances over industry- standard collector boxes and allows users to:

  • Average the flow of 2-4 meters (and removes meters from the average under alarm or user selected conditions)
  • Convert flow units
  • Set up the density of the gas for mass
  • flow measurement
  • Easily configure the individual meters
  • Set up alarms

780S-UHP Ultra High Purity™
780S-UHP Ultra High Purity™

Ultra-High-Purity In-Line mass flow meter; NEMA 4X and Hazardous Area, Approvals: FM, ATEX, CSA, EEx, PED, CE, Cenelec; Smart electronics; flow body sizes from 3/8” to 6”.

+/- 1% of reading + 0.5% of full scale; 0.2%FS repeatability Flow range up to 5000 scfm

Most gases compatible with 316L stainless steel

18-30 Vdc 100 to 240 Vac, 50/60 Hz (optional)

0-5 Vdc 0-10 Vdc 4-20 mA Pulse Modbus FFB Profibus RS232

Field Validation low pressure drop, Alarms, Totaliser, low-flow cut off, 7-10 Ra or 20-25 Ra finish

620S Fast-Flo®
620S Fast-Flo®

Fast response (200ms) insertion mass flow meters for light-industrial use; NEMA 4X; Smart electronics; Insertion probe lengths 3.9” to 24”

+/-1% of full scale & 0.2% repeatability Flow range up to 20000 sfpm

Most non-combustible, non-corrosive gases

18-30 Vdc

0-5 Vdc 0-10 Vdc 4-20 mA

Field Validation Low pressure drop Alarms Totaliser, Low-flow cut off Fast response

730 Accu-Mass®
730 Accu-Mass®

Inline mass flow meter. Quick response (200ms). Low-flow sensitivity. 1/4" to 1 1/4".

Accuracy is ±1% of full scale over 32° to 120°F (0° to 50°C) and 5 to 30 psia (0.3 to 2 barg), flow ranges 0-200 scfm to 0-84 sfpm (air).

Most gases compatible with anodized aluminium and 316 L stainless steel Pressures: 150 psig (10 barg)

15-18 Vdc; 24 Vdc option

0-5 Vdc 0-10 Vdc 4-20 mA

• 200 msec time response • CE approved • NEMA 2 enclosure • Suitable for Methane • In-line bodies with very small footprint

Sierra Instrumentation
Click Photo for Spec Sheet

Description

Features

Input Power

Output Signals

Other

951 Digital Flo-Box ™
951 Digital Flo-Box ™

Ultra-compact digital control/readout and power supply system that is designed to operate a single MFM or MFC

  • 5 digit LED display
  • Front-panel pushbutton set point, calibration and alarms
  • Integral power supply (+/- 15 Vdc) for MFCs and MFMs
  • Compact size—1/8 DIN
  • CE Approved

  • 100Vac 50/60Hz
  • 110 Vac 50/60Hz
  • 240 Vac 50/60Hz

  • Set point 0-5 Vdc only (10K ohm resistance)
  • 2 alarms

  • Optional stand facilitates benchtop usage.
  • Signal input: 0-5 Vdc only, >1M ohm input impedance

954 Digital Flo-Box ™
954 Digital Flo-Box ™

Digital control/readout and power supply system that is designed to operate up to 4 MFMs or MFCs

  • 4 line, 20 character LCD display
  • Front-panel menu adjustable: Flow units, set point etc
  • Integral power supply (+/- 15 Vdc) for MFCs and MFMs
  • Panel mount (1/2 rack) benchtop stand included

  • 100 Vac 50/60Hz
  • 110 Vac 50/60Hz
  • 240 Vac 50/60Hz

  • Analog Outputs: 0-5, 0-10 Vdc and 4-20 mA
  • Digital Output: RS-232 and RS-485

  • Totalizer
  • Gas K-factors
  • Alarms
  • Master/Slave Ratio Control

Compod™ Programmable Control Module
Compod™ Programmable Control Module

With its advanced capabilities, the Compod™, coupled with Sierra’s Smart-Trak® 2 Model 100 mass flow meters or controllers greatly simplifies basic flow control installations and permits networking of multiple instruments using open-source MODBUS RTU protocol.

Two digital outputs and one analog input can be configured by the user for a wide variety of process controls including:

  • Gas mixing and blending
  • Batch control
  • Leak Testing
  • Process monitoring
  • Pressure monitoring and control
  • Gas ratio control
  • Triggering alarms
  • Starting or stopping gas flows automatically under user-defined conditions
  • Gas flow totalization with adjustable pulse output

  • RX485 MODBUS RTU, optically isolated
  • 2 Analogue inputs, user configurable
  • 24Vdc; Compod requires 100mA above power required by 100

  • RX485 MODBUS RTU, optically isolated
  • 2 digital outputs, or analogue relays
  • Analogue pulse output

Compod can be utilized in many common gas process control applications. In simple systems, it replaces expensive PLCs or computers and controls the process directly. In others, it is a key link between a master computer or process controller and the gas control instruments.

Transit Time Ultrasonic Flow Meters
Click Photo for Spec Sheet

Description

Accuracy, Flow Range

Fluid Size

Input Power

Output Signals

Features

205 Innova-Sonic®
205 Innova-Sonic®

Ultrasonic flowmeter system incorporating digital signal processing. Innova-Sonic offers a low power consumption, clear display and user friendly menu selection.

  • ±1.0% of reading
  • 0 to ±40 ft/s (0 to ±12 m/s)

Liquids - non-intrusive so not subject to liquid type or pressure. Pipe Size: 25mm to 5000mm

  • intrusive sensor option
  • 50mm to 10000mm
  • high signal strength

  • 90 to 245 Vac (48-63 Hz)
  • 10 to 36 Vdc

Analog: 0/4 to 20mA (max load 75Ω), Pulse output: 0 to 9999Hz, OCT, (min. and max. frequency is adjustable), Relay output: RS232, RS485

Wall mounted, panel mounted or energy meter versions available. (-40°C to 150°C)

206 Innova-Sonic®
206 Innova-Sonic®

In-line Ultrasonic flowmeter system incorporating digital signal processing. Innova-Sonic offers a low power consumption, clear display and user friendly menu selection. 1" to 10".

  • ±0.5% of reading
  • 0 to ±23 ft/s (0 to ±7 m/s) bidirectional,
  • Repeatability ±0.5% of reading.

Liquids - Pipe Size: 25mm to 250mm Any clean liquid, can tolerate small amounts of suspended solids and air bubbles

  • 90 to 245 Vac (48-63 Hz),
  • 10 to 36 Vdc

Analog: 0/4 to 20mA (max load 75Ω), Pulse output: 0 to 9999Hz, OCT, (min. and max. frequency is adjustable), Relay output: RS232,

Wall mounted, panel mounted or energy meter versions available. -40 to +80°C

210 Innova-Sonic®
210 Innova-Sonic®

Fully field portable ultrasonic system complete with spare battery pack, non-invasive clamp-on transducers, mounting hardware and a unique PalmOne® Personal Digital Assistant (PDA) interface for a totally self-contained measurement package.

  • ±1.0% of reading
  • 0 to ±40 ft/s (0 to ±12 m/s)

Liquids - non-intrusive so not subject to liquid type or pressure. Pipe Size: 25mm to 5000mm

  • 12Vdc(10~36 Vdc)
  • Battery Power (continuous operation of main battery 8 hours + spare battery for 24 hours)

Analogue: 0/4 to 20 mA (max load 750Ω)

PalmOne® 256 MB Tungsten™ T5 PDA with Bluetooth wireless facility. Battery power supply with recharge port and spare battery as standard. -40°C to 80°C

Multivariable Vortex Mass Flowmeters
Click Photo for Spec Sheet

Description

Accuracy, Flow Range

Fluid, Max. pressures

Input Power

Output Signals

Features

240 Innova-Mass® Inline

In-Line Multivariable Mass Flow Meter; Hazardous Area Approvals: FM, CSA, & CE, Smart Electronics; In-Line flow body sizes from 1/4" to 8”

  • Mass Flow (liquids): ± 1.0% of reading;
  • Mass Flow (gases): ±1.5% of reading;
  • Temperature: ±1 0°C;
  • Pressure ±0.4% of full scale;

  • Any gas, liquid or steam
  • Max. Pressure: 1500 psia (100 Bara)
  • Max.Temperature: 400°C

  • 9-36 Vdc, 500 mA
  • 85-240 Vac, 50/60 Hz, 25 Watts (optional)

  • 4-20 mA three simultaneous signals
  • Pulse Output
  • HART RS-485

  • 30:1 Rangeability
  • Reduced Sensitivity to Pipeline vibration
  • 0.2% of mass flow rate repeatability.
  • AGA-8 Algorithms for monitoring natural gas.

241 Innova-Mass® Insertion

  • Insertion Multivariable Mass Flow Meter;
  • Hazardous Area Approvals: FM, CSA, & CE,
  • Smart Electronics;
  • Insertion probe for line sizes 2” to 72”

  • Mass Flow (liquids): ± 1.0% of reading;
  • Mass Flow (gases): ±1.5% of reading;
  • Temperature: ±1 0°C;
  • Pressure ±0.4% of full scale;
  • Flow Range: up to 67000 scfm (air) up to 330000 lb./hr. (saturated steam)

  • Any gas, liquid or steam
  • Max. Pressure: 1500 psia (100 Bara)
  • Max.Temperature: 400°C

  • 9-36 Vdc, 500 mA
  • 85-240 Vac, 50/60 Hz, 25 Watts (optional)

  • 4-20 mA three simultaneous
  • signals
  • Pulse Output
  • HART RS-485

  • 30:1 Rangeability
  • Reduced Sensitivity to Pipeline vibration
  • 0.2% of mass flow rate repeatability.
  • Steam custody transfer model available. AGA-8 Algorithms for monitoring natural gas.

Mass Flow Calibrators
Click Photo for Spec Sheet

Description

Accuracy, Flow Range

Gas & Max. Pressures

Input Power

Output Signals

Features

Features

SL-500 Cal=Trak™ Mass Flow Calibrator

High-precision, cost-effective calibration. Primary Standard. Manufactured to ISO 17025 Standards

±0.4% reading, 5sccm to 50slpm

Suitable for most non-corrosive gases

AC Charger/Adapter: 100-240 Vac, 50-60 Hz

Back-lit LCD display, RS232 serial port with software, parallel printer port (for dedicated printer)

  • No Mercury or other hazardous materials
  • Affordable: Less expensive than most popular secondary standards
  • Convenient: Field portable and battery powered

  • Fast: 1 to 15 sec per flow reading
  • Directly traceable to NIST
  • Generates Calibration Certificate easily
  • CE Approved

SL-800 Cal=Trak™ Mass Flow Calibrator

High-precision, cost-effective calibration. Primary Standard. Manufactured to ISO 17025 Standards

±0.15% reading, 5sccm to 50slpm

Suitable for most non-corrosive gases

AC Charger/Adapter: 100-240 Vac, 50-60 Hz

Back-lit LCD display, RS232 serial port with software, parallel printer port (for dedicated printer)

  • No Mercury or other hazardous materials
  • Affordable: Less expensive than most popular secondary standards
  • Convenient: Field portable and battery powered

  • Fast: 1 to 15 sec per flow reading Directly traceable to NIST
  • Generates Calibration Certificate easily
  • CE Approved

Cal=Trak™ XL High Flow Calibrator

High-precision, cost-effective calibration. Primary Standard. Manufactured to ISO 17025 Standards in NVLAP certified laboratory

±0.25% reading, 5slpm to 500slpm, 4 psi (270 mbar) Differential maximum

Suitable for most non-corrosive gases

AC Charger/Adapter: 100-240 Vac, 1.6 A (max), 50-60 Hz

Back-lit LCD display, RS232 serial port with software, parallel printer port (for dedicated printer)

  • Affordable: Less expensive than most popular secondary standards
  • Convenient: Fully integrated and easy-to-use
  • No Mercury or other hazardous materials
  • CE Approved

  • Compact: 33”H x 24.6”W x 12”D fits easily on benches and replaces large bell provers or arrays of sonic nozzles.
  • Generates Calibration Certificate easily with Cal=Soft software, included
Innova-Switch™ Flow & Level Switches
Click Photo for Spec Sheet

Description

Accuracy, Flow Range

Fluid & Max. Pressure

Input Power

Output Signal

Features

Features

Innova-Switch™

State-of-the-art in gaseous and liquid flow switching or liquid level control. High-resolution thermal differential technique.

  • Flow Range: 0.01 to 5fps liquids and 0.1 to 500 fps gases
  • Repeatability: +/- 1% of set point (Flow) or 1/32" (0.8mm) Level

Gases and liquids up to 3000psi (207bar), -70 to 485°C model dependent

  • 115 Vac, 50/60Hz standard.
  • 230 Vac, 50/60Hz optional,
  • 24 Vdc optional. 3.1 Watt maximum

5A. 250 Vac. DPDT with fail safe capability

CE, CENELEC and CSA approvals

316 SS standard. Hastelloy, Monel, Inconel or other materials optional